Next in thread → Next in month →

Re: [PATCH v2 1/4] spec/vhost-user: fix the VHOST_USER prefix

From
Marc-André Lureau <>
Date
2016-11-28T06:02:28+00:00
ID
Thread
Re: [PATCH v2 1/4] spec/vhost-user: fix the VHOST_USER prefix
On Thu, Nov 24, 2016 at 7:20 AM Wei Wang <> wrote:

Signed-off-by: Wei Wang <>

Reviewed-by: Marc-André Lureau <>

 

---
 docs/specs/vhost-user.txt | 20 ++++++++++----------
 1 file changed, 10 insertions(+), 10 deletions(-)

diff --git a/docs/specs/vhost-user.txt b/docs/specs/vhost-user.txt
index 7890d71..d70bd83 100644
--- a/docs/specs/vhost-user.txt
+++ b/docs/specs/vhost-user.txt
@@ -123,22 +123,22 @@ The communication consists of master sending message requests and slave sending
 message replies. Most of the requests don't require replies. Here is a list of
 the ones that do:

- * VHOST_GET_FEATURES
- * VHOST_GET_PROTOCOL_FEATURES
- * VHOST_GET_VRING_BASE
- * VHOST_SET_LOG_BASE (if VHOST_USER_PROTOCOL_F_LOG_SHMFD)
+ * VHOST_USER_GET_FEATURES
+ * VHOST_USER_GET_PROTOCOL_FEATURES
+ * VHOST_USER_GET_VRING_BASE
+ * VHOST_USER_SET_LOG_BASE (if VHOST_USER_PROTOCOL_F_LOG_SHMFD)

 [ Also see the section on REPLY_ACK protocol extension. ]

 There are several messages that the master sends with file descriptors passed
 in the ancillary data:

- * VHOST_SET_MEM_TABLE
- * VHOST_SET_LOG_BASE (if VHOST_USER_PROTOCOL_F_LOG_SHMFD)
- * VHOST_SET_LOG_FD
- * VHOST_SET_VRING_KICK
- * VHOST_SET_VRING_CALL
- * VHOST_SET_VRING_ERR
+ * VHOST_USER_SET_MEM_TABLE
+ * VHOST_USER_SET_LOG_BASE (if VHOST_USER_PROTOCOL_F_LOG_SHMFD)
+ * VHOST_USER_SET_LOG_FD
+ * VHOST_USER_SET_VRING_KICK
+ * VHOST_USER_SET_VRING_CALL
+ * VHOST_USER_SET_VRING_ERR 

 If Master is unable to send the full message or receives a wrong reply it will
 close the connection. An optional reconnection mechanism can be implemented.
--
2.7.4

-- 

Marc-André Lureau
Next in thread → Next in month →